Jobs configuration

Coverity Documentation

Version
latest

These keys configure worker parallelism during analysis.

Key Type Description
auto Boolean If true, the number of analysis workers to run in parallel is based on the amount of memory and the number of logical processors in the machine. This is the default for a license that is not a FlexNet license.

This key is mutually exclusive with the count and max keys.

count integer The number of analysis workers to run in parallel.

This key is mutually exclusive with the auto and max keys.

max integer The maximum number of analysis workers to run in parallel, subject to limits on the amount of memory and the number of logical processors in the machine. A value of 8 is the default for a FlexNet license.

This key is mutually exclusive with the auto and count keys.

override-worker-limit Boolean When true, allows the number of analysis workers to exceed the recommended value.

This key must be used only with the count key.